Escalator Specs

CZPT  configuration  
Inclination (°) 30(35)
Stage width (mm) 600/800/1000
Horizontal measures two/2 three/three(for 30°), two/2 for 35°
Velocity(m/s) .5
Motor power 8/11/15KW
Handrail bracket Stainless metal
Increase height for 600 3000≤H≤6000/ 6000≤H≤7200
Increase height for 800 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200
Rise height for one thousand 3000≤H≤4800/4800≤H≤6000/6000≤H≤6400/6400≤H≤7200

Engineering Advantages

one.VVVF travel

two.Secure safety technique

three.Ideal running overall performance

four.Superior control technique(German technologies)

five.Comfy and effective

six.Decrease noise and power-saving

Basic safety Functions

1.Lack of section, error stage safety:
If lack of stage (transferring-walk) will or eror period has been checked out, the escalator immediately cease the procedure.
2.Motor above-Ioad safety:
When the current exceeds fifteen% of the recent score, the escalator will automatically slop the operation.
3.CZPTal appliance loop protection:
It provides the automated circuit disconnecting unit to safeguard the circuit and mains parts of the escalator (moving-stroll).
4.Handrail inlet security:
When some international compound has been clipped in the handrail inlet. the  escalator (shifting-walk) will automatically slop the procedure.
five.Comb plate safety system:
When some overseas substance has been clipped in or amongst the combs.the escalator (relocating-stroll) will automatically stop the procedure.
six.Action sagging defense unit:
When there is irregular action bending, the escalator (transferring-stroll) will end the operation prior to the stage coming into into the comb plate
seven.Damaged travel-chain security gadget:
When the generate-chain has been in excess of-stretched or it is broken, the escalator (relocating-stroll) will instantly stop the procedure
8.Damaged stage chain safety:
When the phase (plate) chain has been more than-stretched or it is damaged, the escalator (transferring stroll) will instantly slop the procedure.
9.Over-pace defense:
When  there  is more than-speed to the escalator (shifting  walk),it will instantly cease the operation.
10.Path reversal protection:
When it arrives the unintentional reve  rsal of the course of journey, the escalator (relocating stroll) will automatically stop the operation.
eleven.Security line:
The yellow synthetic resin protection line is found in the front placement and two sides of the escalator tread so that the passengers will not tread in-between the edge of the adjacent step and the group lengthened skirt panel.  The protection line on both sides of the action is increased than the tread floor.   (The  moving-wander  offers the  selective  yellow spray-palmed safety line.)